Best for heavier buildup requiring the most practical advanced cleaning method.
| Unit / Branch |
$349 |
| Building Main |
$649 |
Diamond Scope Limits
- Unit / Branch: 1½–4-inch pipe, up to 50 feet and up to 60 minutes of active cleaning.
- Building Main: 3–6-inch pipe, up to 100 feet and up to 90 minutes of active cleaning.
- Method: One technician-selected method—FlexShaft or hydro jetting—with up to two cleaning passes. Using both methods requires separate authorization.
- Jetting access: An approved cleanout, an operating on-site water source and a safe plan for water containment or discharge are required.
- Footage, time and pass limits apply independently; service ends when the first applicable limit is reached.
Premium Cleaning & Documentation Included
- One affected drain line and one accessible entry point.
- Property, building, unit and affected-fixture confirmation.
- Expanded assessment of the drainage complaint and available access.
- Protection of the immediate work area.
- One advanced cleaning method—FlexShaft or hydro jetting—selected by the technician according to pipe condition, access and practical suitability.
- Pipe-wall cleaning for grease, scale, heavy buildup and light root intrusion where pipe condition and material permit.
- Cleaning-method selection based on pipe material, diameter, condition and available entry point.
- If jetting is unsafe, the technician may use FlexShaft when suitable. If neither method can be used safely, work stops and the unsuccessful-service policy below applies.
- Water-flow test after service.
- Basic cleanup of the immediate work area.
- Digital work-order notes showing the affected line, equipment used and whether flow was restored.
- Check-in and checkout with authorized property personnel when available.
- Camera inspection up to 100 feet on an accessible main line.
- Video footage of accessible findings included.
- Visible-condition notes for grease, scale, roots, offsets, cracks, standing water, foreign objects or deteriorated piping.
- Approximate location of one visible problem area when locating equipment and site conditions permit.
- Before-and-after visible-condition comparison when access and visibility permit.
- Cleaning-result summary identifying restored flow and any remaining visible restriction.
- Enhanced management-ready report combining the cleaning result, visual findings and recommended next action.
- Recommended next action for maintenance, monitoring, repair approval or replacement planning.
Intended result: Restore normal flow when the blockage is serviceable and provide visual evidence for maintenance records, ownership approval or repair planning.